So to me that demonstrates how my booth will react, if the heads are covered. Buying a Paint Booth can seem like there are a lot of requirements that you need to meet from NPFA 33, to OSHA, and then you have permitting required by organizations like the EPA. Spray Booth Systems. [29 CFR 1910.94(c)(3)(iii)(a)] All spray booth overspray filters discarded at the end of each day unless maintained completely in water. One in the paint spraying area, one behind the dry filter and one at the top of the exhaust stack. Viking is the largest manufacturer of spray painting booths in New Zealand. They had a spray paint booth and in the booth was a sprinkler head. This video shows a fire in a small room like a paint booth with no sprinkler head responding, and its flashed over in 2 minutes. It is cup-like in appearance, with an aerodynamically shaped domed end that allows sprayed paint to flow around it. The light fixture and sprinkler head location design were left to the contractor. Then they show a single head responding and its all over in 45 seconds. ft. over 2500 sq. Fire sprinkler heads should be kept free of accumulated deposits. The upstream and downstream protection is meant to cover both sides of the filter media and not the entire booth or duckwork. Re: Spray Booth Fire Protection 102, If this is a dry filter spray booth you actually need 3 separate sprinkler heads as per NFPA 33. This hazard class requires 0.40 gal/sq. I said you can't cover up the sprinkler heads with plastic bags like that, even in a spray booth. You are here: Home / Products / Spray Booth Systems. ... NFPA 13 acknowledges a paint booth as Ordinary Hazard Group 2 – the most stringent design in the code. (2) The sprinkler design area shall not be required to exceed the area of the booth or room in which spraying is conducted. Over the sprinkler head was what looked like a plastic bag. N 15.5.5.2 The automatic sprinkler system for powder coating operations shall be in accordance with the following requirements: (1) Sprinklers shall be designed for Ordinary Hazard (Group 2) as defined in NFPA 13. [29 CFR 1910.107(f)(3)] All spray booth overspray filters should be routinely inspected, cleaned and replaced. Custom booths in all sizes, temperatures and shapes can be made to order from the Market Leaders. [29 CFR 1910.107(b)(5)(ii)] D662,569) designed to protect semi-recessed fire sprinkler heads prior to painting. One common area that there are often questions is what about fire suppression and paint booths, this article will cover the pertinent things you need to know about fire suppression and paint booths. The Coverdome® is the first ever patented paint cover (U.S. Patent No.